TagFlash ECU Programmer has been successfully tested for reading and writing the MB SID310 ECU in boot mode.
Step 1: Connect TagFlash to the ECU MB SID310 Boot Mode
To perform the operation, configure the tool as shown in the provided images and use the Tricore Cable to connect the ECU according to the correct pinout.
Look at the following images for proper connection.
Step 2: Reading/Writing MB SID310 with TagFlash
For reading and writing, use the following driver:
Driver Path: Tool Boot Mode → Infineon Tricore Benchmode Simos Sim → Benchmode SID310 – MERCEDES
Microcontroller: Tricore SAK TC1791
Look at the following images confirming successful reading and writing of MB SID310 with TagFlash (100% OK).
This procedure ensures a reliable boot mode operation for MB SID310 using TagFlash ECU Programmer